Product Description
- Pipes: 20 to 160 mm Single layer & Triple layer
- Fittings: 20 to 160 mm
- Coil Pipe: 20 & 25 mm
- Submersible Delivery Pipe: 90 & 110 mm
Application note: Insulation is necessary at Sub Zero Temperature.
FEATURES
- Proven hot & cold water performance from -0°C to 95° C
- No scaling. Can withstand higher pH values
- UV resistant triple layered pipes are suitable for outdoor installations that are exposed to direct sunlight
- Good chemical resistance - suitable for most industrial liquids
- Heat-fusion jointing results in homogenous plastic system ensuring leak-proof joints
- Very less coefficient of friction, ensures high flow properties, reduce pumping cost
- Antimicrobial inside layer of 3 layered pipe adds to safety against bacterial growth ensuring safe drinking water
- Specially formulated thermax pipes reduce linear expansion / contraction of pipes due to temperature variance, ensuring suitability for outdoor application
- Application note: Insulation is necessary at Sub Zero Temperature.
APPLICATION
- Indoor & outdoor installations of hot & cold water piping systems in residential, commercial & buildings
- Heating system inside buildings including floor, wall & radiator heating
- Drinking water & liquid food transportation
- Solar water heating systems
- Aggresive Chemcials & Pharmaceuticals Piping systems for conveyance of aggressive fluids in Industries
- Application note: Insulation is necessary at Sub Zero Temperature.
| Nominal Size (Outside Diameter) | Wall Thickness |
|---|
| SDR 11 (PN 10) | SDR 7.4 (PN 16) | SDR 6 (PN 20) |
| (mm) | (mm) | (mm) | (mm) |
| 20 | 1.90 | 2.80 | 3.40 |
| 25 | 2.30 | 3.50 | 4.20 |
| 32 | 2.90 | 4.40 | 5.40 |
| 40 | 3.70 | 5.50 | 6.70 |
| 50 | 4.60 | 6.90 | 8.30 |
| 63 | 5.80 | 8.60 | 10.50 |
| 75 | 6.80 | 10.30 | 12.50 |
| 90 | 8.20 | 12.30 | 15.00 |
| 110 | 10.00 | 15.10 | 18.30 |
| 160 | 14.60 | 21.90 | 26.60 |
*Refer to the chemical chart printed Greenfit Technical Manual